Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
1.
J Am Heart Assoc ; : e033605, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38742523

ABSTRACT

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.

2.
J Invasive Cardiol ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38598251

ABSTRACT

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.

3.
Clin Res Cardiol ; 113(1): 68-74, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37294310

ABSTRACT

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic stenosis in patients with intermediate to prohibitive surgical risk. When a single TAVI device fails and cannot be retrieved, TAVI-in-TAVI must be performed acutely, but outcomes of bailout TAVI-in-TAVI have been incompletely appraised. We aimed at analyzing patient, procedural and outcome features of patients undergoing bailout TAVI-in-TAVI in a multicenter registry. METHODS: Details of patients undergoing bailout TAVI-in-TAVI, performed acutely or within 24 h of index TAVI, in 6 international high-volume institutions, were collected. For every case provided, 2 same-week consecutive controls (prior TAVI, and subsequent TAVI) were provided. Outcomes of interest were procedural and long-term events, including death, myocardial infarction, stroke, access site complication, major bleeding, and reintervention, and their composite (i.e. major adverse events [MAE]). RESULTS: A total of 106 patients undergoing bailout TAVI-in-TAVI were included, as well as 212 controls, for a total of 318 individuals. Bailout TAVI-in-TAVI was less common in younger patients, those with higher body mass index, or treated with Portico/Navitor or Sapien devices (all p < 0.05). Bailout TAVI-in-TAVI was associated with higher in-hospital rates of death, emergency surgery, MAE, and permanent pacemaker implantation (all p < 0.05). Long-term follow-up showed that bailout TAVI-in-TAVI was associated with higher rates of death and MAE (both < 0.05). Similar findings were obtained at adjusted analyses (all p < 0.05). However, censoring early events, outlook was not significantly different when comparing the two groups (p = 0.897 for death, and p = 0.645 for MAE). CONCLUSIONS: Bail-out TAVI-in-TAVI is associated with significant early and long-term mortality and morbidity. Thus, meticulous preprocedural planning and sophisticated intraprocedural techniques are of paramount importance to avoid these emergency procedures.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Treatment Outcome , Stroke/etiology , Registries , Aortic Valve/surgery , Risk Factors
4.
Clin Res Cardiol ; 113(1): 86-93, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37391628

ABSTRACT

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve. METHODS: We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed. RESULTS: A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05). CONCLUSIONS: Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Myocardial Infarction , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Aortic Valve Stenosis/surgery , Stroke/etiology
5.
Panminerva Med ; 65(4): 443-453, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37259492

ABSTRACT

BACKGROUND: The clinical impact of coronary artery disease (CAD) on the prognosis of patients undergoing MitraClip implantation is still unclear. METHODS: One thousand nine hundred fifty-three patients undergoing MitraClip implantation included in the multicenter GIOTTO Registry were stratified according to CAD. Endpoints were all-cause death, cardiac death, and re-hospitalization for heart failure at follow-up (median 15.8 months). RESULTS: Although younger, CAD patients were more symptomatic, had worse cardiovascular risk profile, higher burden of comorbidities, more frequently affected by functional MR, with higher left ventricle (LV) diameters and lower ejection fraction (EF). At follow-up, CAD patients showed higher rates of all-cause death (25.4% vs. 19.6%; P=0.002), cardiovascular death (14.0% vs. 10.1%; P=0.007) and re-hospitalization for heart failure (13.9% vs. 10.2%; P=0.011). Dividing the population according to mitral regurgitation (MR) etiology (functional vs. non-functional MR), no differences were observed between CAD and no-CAD patients. At multivariate logistic regression, NYHA III/IV class, prior heart failure hospitalization, severe chronic kidney disease, atrial fibrillation, LV end-diastolic diameter and LVEF<30% but not CAD resulted independent predictors of all-cause death. The same finding was confirmed even after propensity score adjustment. CONCLUSIONS: CAD did not show a relevant impact on mid-term prognosis per se, but seemed to identify a more complex and diseased cohort of patients with worse clinical and functional status.


Subject(s)
Coronary Artery Disease , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Coronary Artery Disease/complications , Coronary Artery Disease/surgery , Heart Failure/complications , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Treatment Outcome
6.
Minerva Cardiol Angiol ; 71(3): 324-332, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35332751

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is emerging as an appealing management strategy for patients with severe aortic stenosis at intermediate, high or exceedingly high risk, but its risk-benefit profile in younger patients is less certain. We aimed to explore the outlook of patients aged 70 years or less and undergoing TAVI at 2 high-volume Italian institutions. METHODS: We retrospectively collected baseline, imaging, procedural and outcome features of patients with age ≤70 years in whom TAVI was attempted at participating centers between 2012 and 2021. Non-parametric tests and bootstrap resampling were used for inferential purposes. RESULTS: A total of 39 patients were included, out of >3000 screened with heart team involvement and >1500 receiving TAVI. Most common or relevant indications for TAVI reduced life expectancy (e.g. cardiogenic shock or severe left ventricular systolic dysfunction), chronic obstructive pulmonary disease, morbid obesity, active or recent extra-cardiac cancer, porcelain aorta, neurologic disability, cirrhosis, or prior surgical aortic valve replacement, as well as extreme cachexia, and Hutchinson-Gilford progeria. At least two contemporary high-risk features were present in most cases. Transapical access was used in 5 (12.8%) cases, and a sheathless approach in 15 (38.5%). A variety of devices were used, including both balloon- and self-expandable devices. Clinical outcomes were satisfactory, despite the high-risk profile, at both short- and mid-term, with no in-hospital death, and 5.1% (95% confidence interval 0-12.8%) mortality at a median follow-up of 15 months (minimum 1; maximum 85). Notably, no case of significant valve deterioration requiring reintervention occurred. CONCLUSIONS: In carefully selected patients with 70 years or less of age and prohibitive risk for surgery or reduced life expectancy, TAVI represents a safe option with a favorable mid-term survival and low rate of adverse events.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Aortic Valve Stenosis/surgery , Treatment Outcome , Aortic Valve/surgery
7.
Minerva Cardiol Angiol ; 70(6): 677-685, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36222602

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has revolutionized the management of aortic stenosis. We aimed at appraising effectiveness of a new self-expandable TAVI device. METHODS: We retrospectively analyzed our institutional experience with Allegra (Biosensors, Morges, Switzerland) for TAVI, focusing on procedural outcomes and 1-month adverse events. We explored the impact of operator experience with this device, dividing patients according to their time of intervention. RESULTS: Between 2018 and 2021, a total of 50 patients underwent TAVI with Allegra, with average age of 81 years, 80% women, and 50% at low or intermediate surgical risk. No major significant difference in baseline patient features were found when comparing Phase 1 and Phase 2, except for baseline left ventricular ejection fraction and New York Heart Association, which were worse in Phase 1. All procedures were performed transfemorally and percutaneously, with predilation in 94% and postdilation in 36%, yielding device success in 98%, and procedural success in 96%. No significant differences in procedural features were found when comparing Phase 1 vs. Phase 2 (all P>0.05). One-month follow-up was also favorable, with no significant difference in adverse outcomes according to phase, and a total of 1 (4%) death, 1 (4%) myocardial infarction, 1 (4%) minor vascular complication, and 4 (8%) permanent pacemaker implantations. Consistent findings were obtained at exploratory 6-month follow-up. CONCLUSIONS: The Allegra TAVI device is associated with favorable short-to-midterm outcomes in experienced hands. Operators already proficient with other devices can achieve satisfactory results even in the early phase of adoption of Allegra.


Subject(s)
Transcatheter Aortic Valve Replacement , Humans , Female , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Stroke Volume , Retrospective Studies , Treatment Outcome , Ventricular Function, Left
8.
Catheter Cardiovasc Interv ; 100(1): 114-119, 2022 07.
Article in English | MEDLINE | ID: mdl-35557027

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has proved beneficial in patients with severe aortic stenosis, especially when second-generation devices are used. We aimed at reporting our experience with Navitor, a third-generation device characterized by intrannular, large cell, and cuffed design, as well as high deliverability and minimization of paravalvular leak. Between June and December 2021, a total of 39 patients underwent TAVI with Navitor, representing 20% of all TAVI cases. Mean age was 80.0 ± 6.7 years, and 14 (36.8%) women were included. Severe aortic stenosis was the most common indication to TAVI (37 [97.4%] cases), whereas 2 (5.3%) individuals were at low surgical risk. Device and procedural success was obtained in all patients, with a total hospital stay of 6.6 ± 4.5 days. One (2.9%) patient required permanent pacemaker implantation, but no other hospital events occurred. At 1-month follow-up, a cardiac death was adjudicated in an 87-year-old man who had been at high surgical risk. Echocardiographic follow-up showed no case of moderate or severe aortic regurgitation, with mild regurgitation in 18 (47%), and none or trace regurgitation in 20 (53%). The Navitor device, thanks to its unique features, is a very promising technology suitable to further expand indications and risk-benefit profile of TAVI.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Male , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
J Invasive Cardiol ; 34(6): E419-E427, 2022 06.
Article in English | MEDLINE | ID: mdl-35551105

ABSTRACT

BACKGROUND: The differential outcomes between pure/predominant aortic stenosis (AS) and mixed aortic valve disease (MAVD) in patients undergoing transcatheter aortic valve implantation (TAVI) are still debated. OBJECTIVE: To evaluate the comparative clinical outcomes of patients with MAVD and AS undergoing TAVI using data from the RISPEVA registry. METHODS: A total of 3263 patients were included. Of the 3263 patients, 656 with concomitant moderate/severe aortic regurgitation constituted the MAVD group and 2607 constituted the AS cohort. Primary endpoints were 30-day mortality and 1-year survival. Postprocedural paravalvular regurgitation (PPVR), cerebrovascular events, bleeding, and vascular complications were assessed at 30 days. RESULTS: In the overall population, 30-day mortality in the MAVD group was higher than in AS patients (4.3% vs 2.6%;P=.02); however, no differences were detected after propensity-score matching (4.1% vs 3.5%; P=.62). One-year survival was comparable between MAVD and AS patients in both unmatched and matched cohorts. Left ventricular ejection fraction, pulmonary artery systolic pressure, and PPVR, but not baseline MAVD, were predictors of 30-day mortality. The incidence of PPVR was higher in the MAVD group vs the AS group; this difference was not confirmed in patients implanted with a balloon-expandable device. CONCLUSION: MAVD per se did not negatively affect patients' prognoses, but appears to identify a more complex cohort of patients with a worse clinical and functional status, probably referred to TAVI in a later stage of the disease. Patients with MAVD had a greater propensity to develop PPVR, which is a known predictor of worse outcome; this tendency seems to be mitigated by the implantation of balloon-expandable valves.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Humans , Propensity Score , Registries , Stroke Volume , Treatment Outcome , Ventricular Function, Left
10.
Panminerva Med ; 64(4): 427-437, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35638242

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs. surgical axillary approaches for TAVI. METHODS: We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses. RESULTS: A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs. 4.2%, P<0.001), leading to more common use of covered stent implantation (13.2% vs. 3.7%, P<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], P=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], P=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], P=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], P=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], P=0.038). CONCLUSIONS: Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Registries , Retrospective Studies , Aortic Valve/surgery , Risk Factors
11.
Sci Rep ; 12(1): 7612, 2022 05 09.
Article in English | MEDLINE | ID: mdl-35534616

ABSTRACT

Transcatheter aortic valve implantation (TAVI) requires thorough preprocedural planning with non-invasive imaging, including computed tomography (CT). The plethora of details obtained with thoraco-abdominal CT represents a challenge for accurate and synthetic decision-making. We devised and tested a comprehensive score suitable to summarize CT exams when planning TAVI. An original comprehensive scoring system (TAVI-CT score) was devised, including details on cardiac, aortic, iliac and femoral artery features. The score was applied to a prospectively collected series of patients undergoing TAVI at our institution, driving decision making on access and prosthesis choice. Different TAVI-CT score groups were compared in terms of procedural success, acute complications, and early clinical outcomes. We included a total of 200 undergoing TAVI between February 2020 and May 2021, with 74 (37.0%) having a low (0-2) TAVI-CT score, 50 (25.0%) having a moderate (3) TAVI-CT score, and 76 (38.0%) having a high (≥ 4) TAVI-CT score. Male gender was the only non-CT variable significantly associated with the TAVI-CT score (p = 0.001). As expected, access choice differed significantly across TAVI-CT scores (p = 0.009), as was device choice, with Portico more favored and Allegra less favored in the highest TAVI-CT score group (p = 0.036). Acute outcomes were similar in the 3 groups, including device and procedural success rates (respectively p = 0.717 and p = 1). One-month follow-up showed similar rates of death, myocardial infarction, stroke, and bleeding, as well as of a composite safety endpoint (all p > 0.05). However, vascular complications were significantly more common in the highest TAVI-CT score group (p = 0.041). The TAVI-CT score is a simple scoring system that could be routinely applied to CT imaging for TAVI planning, if the present hypothesis-generating findings are confirmed in larger prospective studies.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Male , Prospective Studies , Prosthesis Design , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
12.
J Invasive Cardiol ; 34(4): E319-E325, 2022 04.
Article in English | MEDLINE | ID: mdl-35366226

ABSTRACT

BACKGROUND: The next iteration of drug-eluting stents (DESs) for percutaneous coronary intervention (PCI) has focused on bioresorbable polymers and thin struts. The Alex Plus DES is a new-generation sirolimus-eluting device with 70-µm cobalt chromium struts, a 5-µm bioresorbable polymer and a very small profile. Despite such favorable features, limited data are available to estimate the risk-benefit profile of Alex Plus. We aimed at comparing the effectiveness of Alex Plus in real-world practice. METHODS: Retrospective clinical data on patients treated with Alex Plus at our institutions were collected and clinical outcome data over follow-up were obtained, comparing them with those of subjects receiving Xience, a leading DES with permanent polymer. RESULTS: A total of 100 patients (126 lesions) treated with Alex Plus and 753 subjects (1020 lesions) receiving Xience were included. Baseline and procedural features were largely similar in the 2 groups, with the notable exception of age, sex, and left circumflex coronary artery as the target vessel. Clinical follow-up showed that patients with Alex Plus had a significantly higher risk of major adverse clinical event (MACE), mainly driven by an excess in repeat PCI (hazard ratio, 4.81; 95% confidence interval, 2.83-8.20; P<.001). Even after propensity-score matching, Alex Plus was associated with an increased risk of MACE (P<.001). CONCLUSIONS: Our clinical experience to date with Alex Plus has been disappointing, despite the favorable promises. Further improvements are likely needed in the Alex Plus DES, most likely in drug delivery, before this device is considered for routine clinical use in complex patients or lesions.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Coronary Artery Disease/diagnosis , Coronary Artery Disease/etiology , Coronary Artery Disease/surgery , Drug-Eluting Stents/adverse effects , Humans , Percutaneous Coronary Intervention/adverse effects , Propensity Score , Retrospective Studies
13.
Panminerva Med ; 64(1): 1-8, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34309332

ABSTRACT

BACKGROUND: Transcatheter mitral valve repair (TMVR) with MitraClip™ (Abbott Laboratories; Abbott Park, IL, USA) is an established treatment for mitral regurgitation (MR). More than one MitraClip™ may be implanted if a single one does not reduce MR adequately. We aimed to appraise the outlook of patients undergoing implantation of one, two or multiple MitraClip™ for TMVR. METHODS: Exploiting the ongoing prospective GISE Registry of Transcatheter Treatment of Mitral Valve Regurgitation (GIOTTO) Study dataset, we compared patients, procedural details and outcomes distinguishing those receiving one, two or multiple MitraClip™. The primary endpoint was the composite of 1-year cardiac death or rehospitalization for heart failure. Additional endpoints included all cause death, surgical mitral repair, and functional class. Multivariable adjusted Cox proportional hazard analysis was used for confirmatory purposes. RESULTS: As many as 1824 patients were included: 718 (39.4%) treated with a single MitraClip™, and 940 (51.5%) receiving two MitraClip™, and 166 (9.1%) receiving three or more. Significant differences were found for baseline features, including age, female gender, diabetes mellitus, hypertension, chronic obstructive pulmonary disease, prior myocardial infarction, atrial fibrillation, permanent pacemaker, cardiac resynchronization therapy, implantable cardioverter defibrillator, and prior mitral valve repair (all P<0.05). Several imaging features were also different, including left ventricular dimensions, MR severity and proportionality, mitral valve area, flail leaflet, and pulmonary vein flow (all P<0.05). Among procedural features, significant differences were found for anesthesia type, MitraClip™ type, fluoroscopy, device, and operating room times, postprocedural mitral gradient, residual MR, smoke-like effect, device success partial detachment and surgical conversion (all P<0.05). In-hospital death occurred more frequently in patients receiving multiple MitraClip™, and the same applied severe residual MR (all P<0.05). Mid-term follow-up (15±13 months) showed significant differences in the risk of death, cardiac death, rehospitalization for heart failure, and their composites, mainly, but not solely, associated with multiple MitraClip™ (all P<0.05). Adjusted analysis confirmed the significantly increased risk of composite adverse events when comparing the multiple vs. single MitraClip™ groups (P=0.014 for death and rehospitalization, P=0.013 for cardiac death or rehospitalization). CONCLUSIONS: Implantation of one or two MitraClip™ is associated with favorable clinical outcomes. Conversely, bail-out implantation of three or more MitraClip™ may portend a worse long-term prognosis.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Hospital Mortality , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Prospective Studies , Treatment Outcome
14.
Int J Cardiol ; 342: 65-71, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34375704

ABSTRACT

BACKGROUND: We aimed at appraising features and outcomes of patients undergoing MitraClip treatment according to their age. METHODS: We queried the prospective GIse registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO) multicenter registry dataset including 19 Italian centers performing MitraClip implantation, distinguishing patients <80 vs ≥80 years of age. RESULTS: In total, 1853 patients were included, 751 (40.5%) octogenarians and 1102 (59.5%) non-octogenarians. Several baseline and procedural features were significantly different, including gender, regurgitation etiology, and functional class (all p < 0.05). In-hospital outcomes were similarly satisfactory, with death occurring in 18 (2.4%) and 32 (2.9%, p = 0.561), respectively, and improvement in mitral regurgitation in 732 (97.4%) and 1078 (97.8%, p = 0.746), respectively. After a mean follow-up of 15 months, death occurred in 152 (20.2%) and 264 (24.0%), and cardiac death in 85 (11.3%) and 138 (12.5%), respectively (both p > 0.05). Rehospitalization for heart failure and the composite of cardiac death or rehospitalization for heart failure were significantly less common in octogenarians: 63 (8.4%) vs 156 (14.2%, p < 0.001), and 125 (16.6%) vs 242 (22.0%, p = 0.005), respectively. Multivariable analysis showed that these differences were largely due to confounding features, as after adjustment for baseline, clinical and imaging characteristics no significant difference was found for the above clinical endpoints. CONCLUSIONS: Transcatheter mitral valve repair with the MitraClip in carefully selected octogenarians appears feasible and safe, and is associated with favorable clinical outcomes at mid-term follow-up.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged, 80 and over , Cardiac Catheterization , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Prospective Studies , Registries , Treatment Outcome
15.
J Invasive Cardiol ; 33(6): E474-E478, 2021 06.
Article in English | MEDLINE | ID: mdl-34001674

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a safe and beneficial treatment for patients with severe symptomatic aortic stenosis at high and intermediate surgical risk. Success rates for TAVI continue to increase due to more refined procedural approaches and devices, and above all, to the improvements in procedural knowledge by TAVI operators. The development of a new delivery system represents an important evolutionary process in the TAVI procedure, both for the type of device and for the operators, as it may substantially expand indications, success rates, and safety. FlexNav (Abbott Cardiovascular) is a novel delivery system designed to improve ease and precision of TAVI using the Abbott Portico valve. Despite limited results on its advantages, such as those provided in the PORTICO investigational device exemption substudy, uncertainty persists on the actual role of FlexNav in real-world practice. METHODS AND RESULTS: We hereby present our preliminary experience with FlexNav in a consecutive series of 18 patients undergoing TAVI with Portico valve in early 2020 (3 with axillary access). Procedural results were excellent, as shown by the absence of deaths, strokes, and major vascular complications (95% confidence interval, 0%-18.5%), and pacemaker implantation in 3 subjects (21.4%; 95% confidence interval, 4.7%-50.8%). CONCLUSIONS: Despite the small sample size, the present case series suggests that adoption of the FlexNav novel delivery system for TAVI with Portico valve is feasible and safe, and holds the promise of further improving early and long-term results of this procedure.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Humans , Prospective Studies , Prosthesis Design , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
16.
J Cardiovasc Transl Res ; 14(6): 1104-1113, 2021 12.
Article in English | MEDLINE | ID: mdl-33721196

ABSTRACT

Thrombocytopenia after TAVI is common and clinically detrimental. Retrospectively, we observed Portico recipients had a more profound platelet drop than Evolut recipients. We thus investigated periprocedural platelet damage and/orpro-inflammatory state in 64 TAVI recipients at baseline and after implantation. Platelet damage was assessed by annexin V staining and monocyte-phagocytic phenotype was assessed according to CD14/CD36 expression. Serum cytokines were measured in 20 patients. The formaldehyde-based storage solution altered platelets. When, before being loaded onto the delivery system, Portico underwent one additional flushing to those recommended, the receiving patients showed thrombocytopenia, platelet damage, and CD36-monocyte count were mitigated. A general increase in IL-6 was recorded in overall TAVI recipients, but a high serum level of IL-8, a potent thrombocytopenia inducer, was measured in Portico recipients only, including those with extra-rinsed valve. Our study suggests a platelet-injury effect by storage-solution and generates the hypothesis of a role for the biomaterial in stimulating innate-immunity. Larger prospective studies are needed. Graphical Abstract.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Postoperative Complications/etiology , Thrombocytopenia/etiology , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Biomarkers/blood , Cytokines/blood , Female , Humans , Italy , Male , Prosthesis Design , Retrospective Studies
17.
J Invasive Cardiol ; 33(5): E320-E329, 2021 05.
Article in English | MEDLINE | ID: mdl-33739300

ABSTRACT

OBJECTIVES: The management of severe aortic stenosis has been revolutionized by the introduction of transcatheter aortic valve implantation (TAVI), especially in patients at intermediate, high, or prohibitive surgical risk. There is uncertainty, however, regarding the comparative effectiveness and safety of contemporary TAVI devices. METHODS: We queried detailed data from the ongoing national Italian TAVI registry and compared baseline features, procedural details, and 12-month outcomes of Acurate Neo (Boston Scientific), Evolut Pro/R (Medtronic), Lotus (Boston Scientific), Portico (Abbott Vascular), and Sapien/ Sapien S3 Ultra (Edward Lifesciences) transcatheter aortic valves. Several endpoints were collected and appraised, including the composite of death, stroke, myocardial infarction (MI), major bleeding, major vascular complication, surgical aortic valve replacement and transcatheter aortic valve reimplantation, which were deemed major adverse events (MAEs). RESULTS: A total of 1976 patients were included, with 234 treated with Acurate, 703 with Evolut, 151 with Lotus, 347 with Portico, and 541 with Sapien. Twelve-month events were not significantly different among the 5 devices, including death (P=.29) and MAE (P=.21), with the notable exception of major vascular complications, which were more common with Acurate and Sapien (P<.001) and permanent pacemaker implantation, which was more frequent with Lotus and Evolut (P<.001). Differences in MAE were more pronounced in women and subjects with prior cardiac surgery, with the lowest event rates in the Evolut group. Propensity-score adjusted analysis suggested that Acurate, Evolut, Portico, and Sapien were all associated with similarly favorable results, whereas adverse events were more evident with Lotus (P<.05). CONCLUSION: Leading current-generation TAVI devices offer similarly favorable results at mid-term follow-up.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Myocardial Infarction , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Female , Heart , Humans , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Propensity Score , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
18.
Minerva Med ; 112(4): 474-482, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33576201

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become first-line treatment for severe aortic valve stenosis in patients with moderate, high or prohibitive surgical risk. However, access site complications may occur more frequently in extreme body mass index (BMI) categories. The aim of this study was to describe the features and outcomes of patients undergoing TAVI in a comprehensive Italian prospective clinical registry, focusing on BMI classes. METHODS: A national prospective database was queried for baseline, procedural, and outcome details of patients undergoing TAVI according to established BMI categories: underweight (BMI <18.5 kg/m2), normal weight (BMI 18.5-24.9 kg/m2), overweight (BMI 25.0-29.9 kg/m2), and obese (BMI≥30 kg/m2). Short- and long-term outcomes, including major adverse events (MAE), i.e. the composite of death, stroke, myocardial infarction, major vascular complication, major bleeding, or renal failure, were appraised with bivariate and multivariable analyses. RESULTS: A total of 3075 subjects were included, 64 (2.1%) were underweight, 1319 (42.9%) were normal weight, 1152 (37.4%) were overweight, and 540 (17.6%) were obese. Several baseline differences were evident, including gender, diabetes mellitus, renal function, chronic obstructive pulmonary disease, surgical scores, and left ventricular ejection fraction (LVEF) (all P<0.05). Several procedural differences were also evident, including percutaneous approach, predilation, prosthesis type and size (all P<0.05), with postprocedural aortic regurgitation >2+ significantly more common in underweight patients (P<0.05). Nonetheless, unadjusted analysis for one-month outcomes showed similar rates for fatal and non-fatal outcomes, including MAE (all P>0.05), with the notable exception of permanent pacemaker implantation, which was more common in higher BMI classes (P=0.010) Unadjusted analysis for long-term events showed an increased rate of death in underweight patients (P=0.024). Multivariable adjusted analysis confirmed the increased risk of permanent pacemaker implantation in obese patients (P=0.015 when comparing obese vs. normal weight subjects), but disproved differences in long-term mortality and other outcomes (P>0.05 for all comparisons). CONCLUSIONS: Irrespective of BMI class, TAVI is associated with favorable outcomes in surgical high-risk risk patients, with the notable exclusion of permanent pacemaker implantation, which is significantly more common in obese subjects.


Subject(s)
Aortic Valve Stenosis/surgery , Body Mass Index , Transcatheter Aortic Valve Replacement/adverse effects , Analysis of Variance , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/mortality , Female , Humans , Italy , Male , Myocardial Infarction/epidemiology , Overweight/complications , Overweight/epidemiology , Postoperative Complications/etiology , Prospective Studies , Renal Insufficiency/epidemiology , Stroke/epidemiology , Thinness/complications , Thinness/epidemiology , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/statistics & numerical data , Treatment Outcome , Vascular Diseases/epidemiology
20.
Int J Cardiol ; 322: 86-94, 2021 01 01.
Article in English | MEDLINE | ID: mdl-32814109

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is a safe and beneficial treatment for patients with severe symptomatic aortic stenosis at high and intermediate surgical risk. The safety of the procedure continues to improve thanks to more refined procedural approaches and devices but, also and above all, to the accrual of the procedural knowledge and expertise by the operators. The diversification of the approaches and the possibility to tailor the treatment on the individual needs and anatomical features of the patients allows a rapid learning curve in the management of even complications. Indeed, there are several approaches with which TAVI can be carried out: transfemoral arterial, subclavian, transcarotid, transaortic, transaxillary, transapical, and through right anterior thoracotomy. Although transfemoral venous TAVI is less common, it has already have been carried out using caval-aortic punctures. This field is rapidly evolving, and it will be of paramount importance for interventional cardiologists and cardiothoracic surgeons to keep up to date with further developments. This review intends to give an in-depth and update overview of both conventional and innovative TAVI approaches, with the scope to highlight the relevant advantages, major disadvantages, safety aspects and techniques.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Fluoroscopy , Humans , Thoracotomy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...